| Sunday Sep. 20th |
Monday Sep. 21st |
Tuesday Sep. 22nd |
Wednesday Sep. 23rd |
Thursday Sep. 24th |
Friday Sep. 25th |
|---|---|---|---|---|---|
| (13:00 - 17:30) WORKSHOP + REGISTRATION |
(7:30 - 9:00) Registration |
(7:30 - 8:30) Registration |
(7:30 - 8:30) Registration |
(7:30 - 8:30) Registration |
(8:00 - 9:00) Registration |
| (9:00 - 9:40) Opening Session + Awards Announcements |
(8:30 - 10:15) TS 1 / TS 2 |
(8:30 - 10:00) TS 9 / TS 10 |
(8:30 - 10:15) TS 13 / TS 14 |
(9:00 - 10:00) KL5 |
|
| (9:40 - 10:40) AL1 |
(10:00 - 11:00) KL6 |
||||
| (10:40 - 11:40) AL2 |
Coffee Break | Coffee Break | Coffee Break | Coffee Break | |
| Lunch | (10:45 - 12:30) TS 3 / TS 4 |
(10:30 - 11:30) TS 11 / TS 12 |
(10:45 - 12:30) TS 15 / TS 16 |
(11:30 - 12:00) Closing Session |
|
| Lunch | |||||
| (13:15 - 14:15) KL1 |
Lunch | Lunch | |||
| (14:15 - 15:15) KL2 |
(13:00 - 18:30) Conference Tour |
||||
| Coffee Break | (14:15 - 16:00) TS 5 / TS 6 |
(14:30 - 16:00) Poster Session I
|
|||
| (15:45 - 16:45) KL3 |
Coffee Break | ||||
| Coffee Break | |||||
| (16:45 - 17:45) KL4 |
(16:30 - 18:15) TS 7 / TS 8 |
(16:30 - 18:00) Poster Session II |
|||
| (18:15 - 20:30) Welcome Reception |
(18:30 - 22:45) Conference Dinner |
Legend:
TS: Technical Session
AL: Award Lecture
KL: Keynote Lecture
• TECHNICAL SESSIONS (TS) List
•1 Online Monitoring and Fault Diagnosis in HV Equipment
•2 Grounding, Education, Safety, and Standardization in HV Engineering
•3 Lightning, Switching, and Repetitive Transients in Power Systems – I
•4 Insulation Systems for Power Electronic Devices and Emerging Trends in HV Engineering
•5 HV Insulation Systems: Gas, Liquid, Solid, and Vacuum Dielectrics
•6 HV Measurement Techniques and Instrumentation
•7 Lightning, Switching, and Repetitive Transients in Power Systems – II
•8 HV Engineering: Novel Insulation Materials, Technologies for Smart Grids, and Smart Materials
•9 HV Insulation: Transformers, Rotating Machines, Aging, Space Charge, and Industrial Applications – I
•10 HV Cable Insulation: Materials, Aging, and Testing
•11 Renewable Energy Integration to HV Grids and Related Technologies
•12 HV Insulation: Transformers, Rotating Machines, Aging, Space Charge, and Industrial Applications – II
•13 Online Monitoring and Fault Diagnosis in HV Equipment and Outdoor Insulation Performance
•14 HV Measurement Techniques and Insulation Challenges in UHV Power Systems
•15 Insulation Systems and Electromagnetic Fields in HV Engineering
•16 Reliability and Maintenance Strategies for High Voltage Apparatus
• Poster Session List
Topic 1 - Transients and EMC in Power Systems: Lightning, Switching, Repetitive Transients
Topic 2 - High Voltage Measurement Techniques and Instrumentation
Topic 3 - High Voltage Insulation Systems: Gas, Liquid, Solid, and Vacuum Dielectrics
Topic 4 - Performance of Insulators under Environmental Stresses
Topic 5 - High Voltage Cable Insulation: Materials, Aging, and Testing
Topic 6 - Insulation Systems for High Voltage Transformers and Rotating Machines
Topic 7 - Grounding Systems
Topic 8 - Insulation Challenges in UHV AC and DC Power Systems
Topic 10 - Novel Insulation Materials for High Voltage Applications
Topic 11 - Insulation Aging, Space Charge Dynamics, and Industrial Applications
Topic 12 - Reliability and Maintenance Strategies for High Voltage Apparatus
Topic 13 - Online Condition Monitoring and Fault Diagnosis in High Voltage Equipment
Topic 14 - Emerging Trends in High Voltage Engineering: Materials, Technologies, and Applications
Topic 16 - Renewable Energy Integration to High Voltage Grids and Related Technologies
Topic 17 - Smart Materials and Adaptive Systems for High Voltage Engineering
Topic 18 - High Voltage Engineering Education and Workforce Development
Topic 19 - Electromagnetic Fields: Computation, Measurement, and Applications
Topic 20 - Standardization and Safety Protocols in High Voltage Engineering
• TECHNICAL SESSIONS (TS)
•1 Online Monitoring and Fault Diagnosis in HV Equipment
1. Paper ID 1122
An AI pipeline for fault detection in critical infrastructure using drone imagery of substation assets in the transmission grid
Authors: P. Elfers¹; M. V. Cysneiros Aragão¹˒²; S. Azer¹; S. Mörke³; S. Eilers³; S. Konzelmann³
Affiliations:
¹ Jade University of Applied Sciences, Wilhelmshaven, Germany
² Instituto Nacional de Telecomunicações, Santa Rita do Sapucaí, Brazil
³ TenneT TSO GmbH, Bayreuth, Germany
2. Paper ID 1270
Oil-Immersion Power Transformer Fault Diagnosis Method Based on Prototype Networks
Authors: W. Deng¹; Y. Wang¹; X. Hong¹; Y. Wang²; X. Zhuang²; J. Yang²
Affiliations:
¹ State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China
² Guangzhou Branch, EHV, CSG
3. Paper ID 1253
Reliable Inspection of High Voltage Composite Insulator of 230 kV by a Combination of Infrared Thermography with Computed Tomography
Authors: A. H. Shinohara¹; G. J. V. Xavier¹; A. d. P. Pacheco¹; A. C. D. Antonino¹; H. Fujiwara¹; E. G. Costa²; D. Torikai³
Affiliations:
¹ Federal University of Pernambuco, Brazil
² Federal University of Campina Grande, Brazil
³ University of São Paulo, Brazil
4. Paper ID 1208
Assessment of Contact Erosion in SF6 Circuit Breakers Based on Dynamic Resistance and MHD Simulation
Authors: X. Hong¹; Y. Wang¹; J. Zou¹
Affiliation:
¹ Chongqing University, China, People's Republic of
5. Paper ID 1348
Evaluation of Hybrid Filtering Techniques for PD Analysis in Current Transformers with Controlled Degraded Internal Insulation
Authors: A. Silva¹; M. Nunes¹; A. Manito¹; A. Morais¹; C. Silva¹; A. Ribeiro¹; R. Silva¹; G. Junior²; A. Oliveira²
Affiliations:
¹ UFPA, Brazil
² UFSM, Brazil
6. Paper ID 1246
The Correction Method for UAV Induced Electric Field Measurement Distortion in High Voltage Environment
Authors: S. Liu¹; Y. Ma¹; W. Yu¹; X. E¹; J. Liu²; H. Mei²
Affiliations:
¹ Dali Bureau, EHV Power Transmission Company of CSG
² Tsinghua Shenzhen International Graduate School, Tsinghua University
•2 Grounding, Education, Safety, and Standardization in HV Engineering
1. Paper ID 1123
Performance of alternative topologies of tower grounding system composed of counterpoise with vertical or slant rods
Authors: A. R. Justo de Araujo¹; W. L. Manzi de Azevedo¹; J. Pissolato Filho¹; B. Kordi²
Affiliations:
¹ University of Campinas, Brazil
² University of Manitoba, Canada
2. Paper ID 1135
Accelerated Experimental Investigation of Grounding Material Degradation and Implications for Earthing Performance
Authors: E. D. Ellinas¹; V. P. Androvitsaneas¹; E. C. Senis⁴; N. Kokkinos⁴; V. T. Kontargyri³; E. C. Pyrgioti²; A. Moropoulou⁵; E. V. Hristoforou¹; C. A. Christodoulou¹
Affiliations:
¹ National Technical University of Athens, School of Electrical and Computer Engineering
² University of Patras, Department of Electrical and Computer Engineering
³ University of West Attica, Department of Electrical and Electronics Engineering
⁴ ELEMKO S.A.
⁵ National Technical University of Athens, School of Chemical Engineering
3. Paper ID 1343
Methodology for Reliable Grounding Analysis in Existing Substations Under Incomplete Design Data Conditions
Authors: W. Santos; M. Franco
Affiliation: Focus Engenharia Elétrica, Brazil
4. Paper ID 1136
Effect of Corrosion Layers on Counterpoise-Based Transmission Tower Grounding Systems
Authors: A. R. Justo de Araujo¹; W. L. Manzi de Azevedo¹; J. E. Guevara Asorza¹; T. Papadopoulos²; J. P. Filho¹
Affiliations:
¹ University of Campinas, Brazil
² Aristotle University of Thessaloniki
5. Paper ID 1172
High voltage interdisciplinary education: from insulation discharge to discharge plasma application
Authors: B. Zhang; G.-J. Zhang
Affiliation: State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049, China
6. Paper ID 1169
Partial Discharge in DC Aerospace Systems: Towards Standardized Detection and Defect Classification
Authors: V. Werle¹; B. Schober²; O. Gavard¹; U. Schichler²
Affiliations:
¹ Amphenol-Socapex Engineering Laboratory, France
² Graz University of Technology, Austria
•3 Lightning, Switching, and Repetitive Transients in Power Systems – I
1. Paper ID 1344
Induction of surface currents in tissues by electromagnetic fields induced by lightning currents
Authors: C. Rivera¹; F. Román¹; J. Rodriguez¹; A. Cristancho¹; E. Pineda¹
Affiliation:
¹ Universidad Nacional de Colombia, Colombia
2. Paper ID 1321
Analysis of Lightning-Induced Voltages in Low-Voltage Lines with Experimentally Characterized Surge Protective Devices
Authors: A. Piantini¹; C. Braz¹; C. Kodaira¹
Affiliation:
¹ University of São Paulo (IEE/USP), Brazil
3. Paper ID 1140
Experimental Study on the 8/20 μs Surge Withstand Capability of Transient Voltage Suppressor Diodes Subjected to Multiple Impulse Currents
Authors: N. Gkonou¹; G. Peppas²; E. Petrou¹; E. Pyrgioti³; T. Tsovilis¹
Affiliations:
¹ Aristotle University of Thessaloniki
² Technical University of Crete
³ University of Patras
4. Paper ID 1266
Influence of the Tower Surge Impedance on the Lightning Overvoltages at the LV Circuit of Hybrid Overhead Lines
Authors: L. Batista Moraes¹; A. Piantini¹
Affiliation:
¹ University of São Paulo, Brazil
5. Paper ID 1228
A Comparative Study regarding Transmission Tower Modeling for Lightning Surge Analysis by means of Electromagnetic Transients Calculation and Reduced Model Measurements
Authors: G. X. Barbosa¹; A. C. Franklin¹; W. C. Boaventura¹; I. J. S. Lopes¹
Affiliation:
¹ Federal University of Minas Gerais (UFMG), Brazil
6. Paper ID 1263
Assessing the impact of insulator flashover modeling on the calculation of the lightning outage rate of transmission lines
Authors: F. Silveira¹; G. Zago¹; S. Visacro¹
Affiliation:
¹ Federal University of Minas Gerais, Brazil
•4 Insulation Systems for Power Electronic Devices and Emerging Trends in HV Engineering
1. Paper ID 1216
Effect of Pore Heterogeneity on Dielectric Distribution and Breakdown Characteristics of Oil-Impregnated Aramid Paper
Authors: Y. He¹; L. Yang¹; W. Zhao¹; J. Hu¹; G. You¹
Affiliation:
¹ State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University
2. Paper ID 1272
Application and promotion of thermal oxygen cracking method for recycling waste silicone rubber from high-voltage power equipment
Authors: W. Xu¹; L. Cheng¹; S. Chen¹; Z. Chen¹
Affiliation:
¹ Chongqing University, China, People's Republic of
3. Paper ID 1279
Mechanisms of Pore Structure Control on Superhydrophobic Steel-Cored Aluminum Stranded Conductors
Authors: M. Chen¹; L. Wei¹; C. Hong¹; J. Bai²; H. Zeng²; X. Zhao¹
Affiliations:
¹ Chongqing University, China
² Electric Power Research Institute, Guizhou Power Grid Co., Ltd., China
4. Paper ID 1235
Plastic Enhancement Behavior of AZ31B Magnesium Alloy Treated by High-Voltage Short Pulsed Current
Authors: Z. Wu¹; C. Li¹; Y. Zhou¹; P. Wang¹; D. Chen¹
Affiliation:
¹ State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University
5. Paper ID 1334
Impact of Environmental Factors on Breakdown Characteristics of Air Insulation in Power Distribution Component for Electric Aircraft
Authors: Y. Serdyuk¹; A. Koseoglu¹
Affiliation:
¹ Chalmers University of Technology, Sweden
6. Paper ID 1147
Early-warning Features from Discharge-Waveform Monitoring of Metallized Film Capacitors in Pulsed Overload Regimes
Authors: X. Sun¹; F. Wang¹; Y. Wu¹; Y. Lu¹; G. Li¹; J. Pan¹; J. Li¹
Affiliation:
¹ State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, China
•5 HV Insulation Systems: Gas, Liquid, Solid, and Vacuum Dielectrics
1. Paper ID 1197
Molecular Dynamics Investigation on the Inhibition Mechanism of Composite Antioxidants on Gas Evolution in Vegetable Insulating Oils under Thermal Oxidation
Authors: S. Luo¹; C. Wei¹; J. Li¹
Affiliation:
¹ Chongqing University, China
2. Paper ID 1220
Thermal Stability and Microscopic Mechanisms of Natural and Modified Esters as Impregnating Agents for Capacitors
Authors: J. Zhang¹; J. Hao¹; C. Fan²; B. Luo²; Q. Huang³; D. Lu¹
Affiliations:
¹ State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
² Electric Power Research Institute, China Southern Power Grid, Guangzhou 510663, China
³ Electric Power Research Institute of Guangzhou Power Supply Bureau, Guangdong Power Grid Co., Ltd., Guangzhou 510410, China
3. Paper ID 1179
Influence of Partial Discharges and Surface Charging on AC Breakdown of Triple Junctions
Authors: I. G. Folkestad¹; H. K. H. Meyer²; F. Mauseth¹
Affiliations:
¹ Norwegian University of Science and Technology (NTNU), Trondheim, Norway
² SINTEF Energy Research, Trondheim, Norway
4. Paper ID 1132
Lightning impulse flashover strength of insulating down-conductors employed in electrically insulated LPS
Authors: P. Tsouris¹; P. Samaras¹; P. Mikropoulos¹; T. Tsovilis¹; N. Kokkinos²
Affiliations:
¹ Aristotle University of Thessaloniki, Greece
² ELEMKO S.A.
5. Paper ID 1108
Measurement of Surface Charge Accumulation on Cone-Type DC-GIS Spacer in CO₂ Gas
Authors: Z. Li¹; M. Sato¹; T. Umemoto¹; A. Kumada¹; K. Hidaka¹; T. Yasuoka²; Y. Hoshina²; Y. Sho²; M. Shiiki²
Affiliations:
¹ The University of Tokyo, Japan
² Toshiba Energy Systems & Solutions Corporation, Japan
6. Paper ID 1153
Prediction of Micro-protrusion Temperature Distribution in Vacuum Breakdown Based on Deep Learning
Authors: H. Luo¹; S. Li¹; Z. Fu¹; C. Zhang¹
Affiliation:
¹ Nanjing University of Aeronautics and Astronautics, China
•6 HV Measurement Techniques and Instrumentation
1. Paper ID 1109
Assessment of Insulation Margin for Electric Heavy-Duty Vehicle Motors Based on Simulation and PDIV Testing
Authors: B. Li¹; M. Chen¹; N. Sun¹; J. Liu¹; W. Feng¹; Z. Dai¹; T. Yu²; P. Wang²
Affiliations:
¹ State Key Laboratory of Engine and Powertrain System, Weichai Power Co., Ltd.
² Sichuan University, China, People's Republic of
2. Paper ID 1316
Optical Detection of Partial Discharges – Advantages and Limitations for Three Different Applications
Authors: R. Plath¹
Affiliation:
¹ Technische Universität Berlin, Germany
3. Paper ID 1102
Partial Discharge Measurement for DC with Superimposed Transients
Authors: Y. Xia¹; L. C. Castro Heredia¹; A. Rodrigo Mor²; M. G. Niasar¹
Affiliations:
¹ TU Delft, Netherlands
² Universitat Politècnica de València, Spain
4. Paper ID 1106
Measuring Fast Transient Voltages – Reducing Uncertainty Related to Puncture Testing of Insulators in Air
Authors: J. Klüss¹; J. Hällström²; A. Merev²; K. Lahti³; M. Niittymäki³; P. Roccato⁴; A.-P. Elg¹; M. Kujda⁵; G. P. Scialpi⁴; T. G. Aguado⁶; J. Rovira⁶; D. Österbacka²; J. Meisner⁷
Affiliations:
¹ RISE Research Institutes of Sweden, Sweden
² VTT Technical Research Centre of Finland, Finland
³ TAU Tampere University, Finland
⁴ INRIM Istituto Nazionale di Ricerca Metrologica, Italy
⁵ Haefely AG, Switzerland
⁶ FFII-LCOE Fundación para el Fomento de la Innovación Industrial, Spain
⁷ PTB Physikalisch-Technische Bundesanstalt, Germany
5. Paper ID 1171
Time-Resolved Measurement of Current and Voltage for Minimum Ignition Energy Determination
Authors: S. Passon¹; J. Dymke¹; T. Gerdes¹; F. Schilling¹; T. Engel¹; D. Markus¹
Affiliation:
¹ Physikalisch-Technische Bundesanstalt (PTB), Germany
6. Paper ID 1127
Measuring Error of Calibrated HV Dividers for the Characterization of Chopped Lightning Impulses According to IEC 60060-2
Authors: M. Kujda¹; U. Hammer¹; C.-H. Stuckenholz¹
Affiliation:
¹ Haefely AG, Switzerland
•7 Lightning, Switching, and Repetitive Transients in Power Systems – II
1. Paper ID 1116
Interaction of Power Transformers and Circuit Breakers at 145 kV: A Benchmark between Vacuum and SF6 Switching Technology
Authors: T. Wendlinger¹; M. Bauer²; T. Manthe²; J. Weisker³; S. Giere³
Affiliations:
¹ Siemens Energy, Power Transformers Linz, Austria
² Siemens Energy, Power Transformers Nuremberg, Germany
³ Siemens Energy, Switchgear Berlin, Germany
2. Paper ID 1264
Implementation of a Scale Model for the Analysis of Lightning Overvoltages in a 440 kV Transmission Line
Authors: T. F. dos Santos¹˒²; A. Piantini²; M. Shigihara²; L. B. Moraes²
Affiliations:
¹ Federal Catarinense Institute (IFC), Brazil
² University of São Paulo, São Paulo, Brazil
3. Paper ID 1276
Impulse Overvoltages for the Study of Lightning Performance of High-Voltage Transmission Lines
Authors: F. Silveira¹; A. Piantini²; G. Bueno¹; L. Moraes²; M. Shigihara²
Affiliations:
¹ Federal University of Minas Gerais (UFMG), Brazil
² University of São Paulo (USP), Brazil
4. Paper ID 1287
Investigation of Overvoltages in the 138 kV Circuit of a Hybrid Overhead Line
Authors: W. Matos; A. Piantini
Affiliation:
University of São Paulo (USP), Brazil
5. Paper ID 1309
Study on Fast Switch Transient Recovery Voltage Characteristics in 750 kV Systems Equipped with Fault Current Limiters
Authors: X. Zhao; J. Deng; C. Li; M. Xu; J. Deng
Affiliation:
Xi'an Jiaotong University, China
6. Paper ID 1362
A Damping-Factor-Based High Frequency Model of Transformer for Fast Transient Studies
Authors: M. Eslamian¹; E. Rahimpour²
Affiliations:
¹ Hitachi Energy, Germany
² Technical University of Applied Sciences Würzburg-Schweinfurt (THWS), Germany
•8 HV Engineering: Novel Insulation Materials, Technologies for Smart Grids, and Smart Materials
1. Paper ID 1333
A Multi-gas Sensor Enabled Lifecycle-Assessment Framework for Green Gas Insulated Equipment
Authors: D. Wei¹; N. Guo¹; W. Zhong¹; W. Gao¹; R. Potyrailo²; S. Shan²; I. Ndiaye²; J. Zhou²; Y. Cao¹
Affiliations:
¹ University of Connecticut, United States of America
² GE Vernova
2. Paper ID 1341
Loss Measurements from Harmonics in HVAC Cables – Calorimetric vs Electric Methods
Authors: A.-P. Elg¹; A. Ramirez²; J. Rovira²; A. Klasson¹; O. Holte⁴; P. Roccato³; T. Nieminen¹; D. Willen⁴; A. Khamlichi²
Affiliations:
¹ RISE, Sweden
² FFII, Spain
³ INRIM, Italy
⁴ NKT, Denmark
3. Paper ID 1194
Self-healing Insulation Defects in GIS and GIL Equipment Based on Dual-Component Microcapsules
Authors: B. Chen¹; P. Sun¹; W. Sima¹; W. Tang¹
Affiliation:
¹ Chongqing University, School of Electrical Engineering, China
4. Paper ID 1345
Transfer Learning Assisted Development of Disulfide Epoxy Vitrimer Insulation Material with Excellent Comprehensive Properties
Authors: W. Li¹; Y. Zhang¹; J. Luo²; M. Zhang²; G.-J. Zhang¹
Affiliations:
¹ State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, Shaanxi 710049, China
² School of Computer Science, National Key Laboratory for Multimedia Information Processing, PKU-Anker LLM Lab, Peking University, Beijing 100871, China
5. Paper ID 1215
Self-healing Properties of Epoxy-based Composite Insulating Materials Modified by Water-induced Curing Microcapsules
Authors: X. Liu; P. Sun; W. Sima; C. Niu; J. Xu; W. Tang
Affiliation:
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
6. Paper ID 1195
Research on Performance Enhancement of High-Performance Biobased Isophorone
Authors: P. Zhang¹; P. Guo²; C. Zhao¹; W. Xu¹; Z. Huang¹; J. Li¹; Y. Zhang¹; Q. Fu³
Affiliations:
¹ State Key Laboratory of Power Transmission and Transformation Equipment Technology, College of Electrical Engineering, Chongqing University, China
² Shandong Electric Power Equipment Co., Ltd.
³ Electric Power Research Institute of Guangdong Power Grid Co., Ltd.
•9 HV Insulation: Transformers, Rotating Machines, Aging, Space Charge, and Industrial Applications – I
1. Paper ID 1361
Effect of High Temperature and DC/AC Superimposed Voltage on Capacitive Performance of Polypropylene
Authors: Z. Ran; Y. Liu; L. Meng; Y. Zhang; Q. Li
Affiliation:
Tsinghua University, China
2. Paper ID 1249
Voltage-Resolved Dielectric Loss Factor as a Relative Indicator of Insulation Degradation in Aged Stator Bars
Authors: Z. Frána; J. Kopřiva; P. Trnka
Affiliation:
FEL ZCU, Czech Republic (Czechia)
3. Paper ID 1120
Optical Investigation of Slow-Mode Positive and Negative Streamers in Mineral Oil
Authors: A. Pourebrahim Shishavan¹; I. Madshaven²; D. Linhjell²; L. Lundgaard²; K. Niayesh¹
Affiliations:
¹ Norwegian University of Science and Technology, Norway
² SINTEF Energy Research
4. Paper ID 1143
Evaluation of dielectric properties of synthetic ester liquid at negative lightning impulse voltage
Authors: P. Rozga¹; F. Wang²; F. Stuchala¹; J. Li²; M. Lalik¹
Affiliations:
¹ Lodz University of Technology, Poland
² Chongqing University, China
5. Paper ID 1204
A Non-Destructive Evaluation Method for the Electrical Properties of Insulating Oil Based on Terahertz Technology
Authors: S. Zhang¹; L. Cheng¹; Z. Gong¹; Q. Wang¹˒²; Y. He¹; R. Liao¹
Affiliations:
¹ State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, China
² Yunnan Power Grid Co., Ltd., Kunming Power Supply Bureau, China
•10 HV Cable Insulation: Materials, Aging, and Testing
1. Paper ID 1111
In Situ SAXS/WAXS Investigation on the Structure-Property Relationship of Polypropylene Cable Insulation under Deformation
Authors: Y. Guo; X. Zhang; W. Wei; Y. Yang; J. He; S. Huang
Affiliation:
Tsinghua University, China
2. Paper ID 1227
Influence of Partial Discharge in Void on Adjacent Interfaces in Solid Insulation
Authors: N. F. Adan¹˒²; S. Li¹; S. Rowland¹
Affiliations:
¹ University of Manchester, United Kingdom
² Universiti Tun Hussein Onn Malaysia, Malaysia
3. Paper ID 1184
Detection of Cable Insulation and Buffer Layer Defects Based on Potential Decay Measurement
Authors: S. Yu¹; S. Chen²; X. Yu¹; X. Peng¹; Y. Tang²; W. Li²; C. Ren²
Affiliations:
¹ Guangdong Key Laboratory of Electric Power Equipment Reliability, Electric Power Research Institute of Guangdong Power Grid Co., Ltd., China
² Beijing International S&T Cooperation Base for Plasma Science and Energy Conversion, Institute of Electrical Engineering, Chinese Academy of Sciences, China
4. Paper ID 1302
Characterisation of PRPD Patterns and Electric Field Behaviour in Ageing Insulation with Embedded Cavities
Author: I. K. Kyere
Affiliation:
Vaal University of Technology, South Africa
5. Paper ID 1207
Study on the Effect of Ethylene Content in POE on the Properties of Polypropylene Cable Semiconductive Shielding Materials
Authors: M. Liu¹; X. Zhang¹; C. Tong¹; X. Xiong²; W. Wei¹; Y. Yang¹; Q. Li¹; J. He¹; S. Huang¹
Affiliations:
¹ State Key Laboratory of Power System Operation and Control, Department of Electrical Engineering, Tsinghua University, Beijing, China
² School of Electrical Engineering, Guangxi University, Nanning, Guangxi, China
•11 Renewable Energy Integration to HV Grids and Related Technologies
1. Paper ID 1300
Influence of Shunt Compensation on Power System Small-Signal Stability with Battery-Integrated Power Converters
Authors: F. E. do Nascimento Morais¹; É. Gurski²; G. Carvalho Prezotto¹; L. F. Normandia Lourenço²; M. Barbosa de Camargo Salles¹; R. Machado Monaro¹
Affiliations:
¹ Polytechnic School of the University of São Paulo (USP), São Paulo, Brazil
² Institute of Energy and Environment (IEE-USP), São Paulo, Brazil
2. Paper ID 1280
Study on Characteristic Gas and Internal Pressure Development of Lithium-ion Battery Under Overcharging
Authors: W. Zhang; J. Wang; S. Zhang; H. Liu; X. Duan; T. Liu; Y. Peng; K. Chen; W. Chen
Affiliation:
Chongqing University, Chongqing, China
3. Paper ID 1303
Impacts of Active Power Loop Tuning on the Small-Signal Stability of Grid-Forming Inverters Under Different Reactive Power Control Strategies
Authors: H. J. Khan¹; E. Gurski²; M. B. d. C. Salles¹; L. F. N. Lourenço²; F. E. M. Morais¹; G. C. Prezotto¹
Affiliations:
¹ Polytechnic School of the University of São Paulo (USP), São Paulo, Brazil
² Institute of Energy and Environment, University of São Paulo (IEE-USP), São Paulo, Brazil
•12 HV Insulation: Transformers, Rotating Machines, Aging, Space Charge, and Industrial Applications – II
1. Paper ID 1328
Interface Charge and DC Breakdown Characteristics of Ester-based Insulating Oil-Paper Insulations
Authors: J. Hao; J. Li; H. Han; H. Zhao; X. Sun; R. Liao
Affiliation:
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, China
2. Paper ID 1360
Capacitive Performance of PI Films Containing Spiral Structures under DC/AC Voltages
Authors: Z. Ran; Y. Zhang; L. Meng; Y. Liu; Q. Li
Affiliation:
Tsinghua University, China
3. Paper ID 1105
Transport Phenomena of Synthetic Ester Liquid through Mineral Oil Impregnated Cellulose Paper
Authors: J. Chen; M. Teixeira; Q. Liu
Affiliation:
The University of Manchester, United Kingdom
•13 Online Monitoring and Fault Diagnosis in HV Equipment and Outdoor Insulation Performance
1. Paper ID 1200
A Comparative Study of Axis-Aligned, Oriented, and Optimization-Based Bounding Box Strategies for Insulator Detection
Authors: G. Rodrigues¹; B. Araujo¹; J. de Oliveira²; E. da Costa¹; G. Xavier²; T. Ferreira²˒³
Affiliations:
¹ Federal University of Campina Grande, Brazil
² Federal University of Sergipe, Brazil
³ INESC P&D Brasil, Brazil
2. Paper ID 1231
Circuit Modeling and Experimental Validation of Leakage Current in Polluted Polymeric Insulators
Authors: C. Silva¹; M. Nunes¹; A. Manito¹; A. Morais¹; A. Silva¹; R. Silva¹; A. Ribeiro¹; A. Cardoso²; W. Bassi³
Affiliations:
¹ Federal University of Pará, Brazil
² University of Porto, Portugal
³ University of São Paulo, Brazil
3. Paper ID 1318
Research on the Detection of the Opening and Closing States of High-Voltage GIS Isolating Switches Based on Mechanical Vision Technology and Vibration Signal Analysis
Authors: W. Cheng¹; Y. Zhao¹; S. Li¹; G. Liu¹; H. Zhang²; X. Zhao²
Affiliations:
¹ Hefei University of Technology, China
² State Grid Chongqing Electric Power Company Construction Branch, China
4. Paper ID 1319
Simulation by the Finite Element Method and Comparison with Experimental Data of the Leakage Current in Polluted High Voltage Insulators
Authors: R. Nascimento¹; M. Nunes¹; A. Manito¹; A. Morais¹; W. Bassi¹; A. Cardoso²; C. Silva¹; A. Ribeiro¹; E. Simões¹; E. Dias¹
Affiliations:
¹ Federal University of Pará, Brazil
² University of Porto, Portugal
5. Paper ID 1281
Concentric Multi-Pass Cavity-Enhanced Raman Spectroscopy for Trace Fault-Gas Sensing in Power Transformers
Authors: T. Liu; J. Wang; M. Wang; W. Zhang; X. Duan; H. Liu; Y. Peng; K. Chen; W. Chen
Affiliation:
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
6. Paper ID 1245
Research on Performance Differences of Fabry-Perot Ultrasonic Sensors Based on Different Coupling Structures in Detecting Partial Discharge in Oil-Paper Insulation
Authors: H. Liu¹; Z. Shu¹; H. Tian²; J. Wang¹; X. Duan¹; W. Zhang¹; Y. Song¹; Z. Wang³; W. Chen¹
Affiliations:
¹ State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, China
² China Electric Power Research Institute, China
³ Chengdu Power Supply Company of State Grid Sichuan Electric Power Co., Ltd., China
•14 HV Measurement Techniques and Insulation Challenges in UHV Power Systems
1. Paper 1335
Study on the Improvement of Current-Carrying Capacity of 320 kV HVDC Cables with Extruded Insulation
Authors: A. Skoura; P. Kamtsios; E. Nicolopoulou; N. Ilia; C. Christodoulou; I. Gonos
Affiliation:
National Technical University of Athens, Greece
2. Paper 1301
A High-Voltage Sub-Nanosecond Pulse Measuring Device
Authors: Y. Xu; C. Li; S. Zhang; S. Weng; K. Wang; Y. Zhou
Affiliation:
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
3. Paper 1165
Impulse current testing up to 200 kA with standardised waveforms
Authors: S. Passon; F. Gerdinand; J. Meisner; F.-T. Ullmann
Affiliation:
Physikalisch-Technische Bundesanstalt, Germany
4. Paper 1219
Pressure Normalized Characteristics of First Streamer Charge in a One Meter Positive Rod Plane Gap under Reduced Air Pressure
Authors: C. Liu; Y. Huang; Y. Huang; Z. Wang; Z. Shi; H. He
Affiliation:
Huazhong University of Science and Technology, China
5. Paper 1291
Non-contact voltage measurement method based on array electric field sensors
Authors: S. Wu¹; Y. Ye¹; X. Liu¹; X. Jiang¹; H. Zhang¹; R. Bi¹; J. Yang²; Z. Hu²; J. Hu¹
Affiliations:
¹ State Key Laboratory of Power System Operation and Control, Tsinghua University, China
² Guangzhou Branch EHV, CSG, Guangdong, China
6. Paper 1225
Miniaturization of Antennas Using Fractal Geometries for Partial Discharge Detection
Authors: B. Cardoso Ferreira da Silva¹; K. Rocha de Oliveira¹; M. Evangelista Santos¹; R. Santana Lima¹; G. V. Rocha Xavier¹; H. Sales Silva²
Affiliations:
¹ Federal University of Sergipe, Brazil
² University of Brasília, Brazil
•15 Insulation Systems and Electromagnetic Fields in HV Engineering
1. Paper 1160
Mapping Electrical Stress and Contact Temperatures under Pressure Variations in Itaipu’s SF6 Gas-Insulated Switchgear
Authors: R. Graeff¹; A. E. Ramon Osorio Paredes²; L. F. Zubeldia Dal Posso¹; E. L. Marques¹
Affiliations:
¹ Itaipu Parquetec, Brazil
² Itaipu Binacional, Paraguay
2. Paper 1338
Representation of Five-Winding Transformers in ATPDraw
Authors: I. Lima Souza; W. Boaventura
Affiliation:
Federal University of Minas Gerais
3. Paper 1239
The effect of cyanobiphenyl additive on the thermal oxygen aging characteristics of soybean insulating oil
Authors: C. Zhao; P. Guo; C. Wang; K. Tian; W. Chen; J. Li; Z. Huang; P. Zhang; R. Lin
Affiliation:
Chongqing University, China
4. Paper 1183
Relationship Between Hydrogen Absorption Performance and Molecular Structure for Different Ester-based Liquid: A DFT Stud
Authors: J. Hao¹; D. Lu¹; Z. Bian¹; H. Zhao¹; H. Song²; Q. Huang²
Affiliations:
¹ State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, China
² CSG Guangdong Guangzhou Power Supply Bureau, China
5. Paper 1299
Influence of Bulk–Surface Conductivity Ratio on Charge Accumulation of GIL Spacers under Temperature Gradient
Authors: C. Li; J. Shi; J. Dai; J. Deng
Affiliation:
Xi'an Jiaotong University, China
6. Paper 1327
DC Conductivity and Space Charge Characteristics of Ester-Based Insulating Oil-Immersed Pressboard
Authors: J. Li¹; J. Hao¹; Z. Han¹; H. Zhao¹; H. Song²; Q. Zhao³
Affiliations:
¹ State Key Laboratory Of Power Transmission Equipment Technology, School Of Electrical Engineering, Chongqing University, China
² CSG Guangdong Guangzhou Power Supply Bureau, China
³ State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, China
•16 Reliability and Maintenance Strategies for High Voltage Apparatus
1. Paper 1271
Rapid and Non-destructive Moisture Detection in Oil–Paper Insulation by Near-Infrared Spectroscopy
Authors: W. Sun; H. Li; X. Chen; D. Zhang; Y. Li; G. Zhang
Affiliation:
Xi'an Jiaotong University, China
2. Paper 1137
A Sequential Monte Carlo Approach for Reliability Evaluation of Offshore Wind Farms Considering Cable Aging Effects
Authors: Í. A. J. W. Silva Meireles¹˒³; A. A. d. Oliveira¹; R. A. Ribeiro de Moura¹; V. Albernaz Lacerda²; F. A. d. Assis¹
Affiliations:
¹ The Federal University of São João del-Rei, Brazil
² Universitat Politècnica de Catalunya
³ Federal Center for Technological Education of Minas Gerais
3. Paper 1312
Vibration Characteristic Analysis of Cable GIS Terminations in Substation
Authors: Z. Zhang; Z. Jia
Affiliation:
Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
4. Paper 1282
Impact of Feature Representation on Intelligent Models under Measurement Uncertainty in Dissolved Gas Analysis
Authors: M. BOUZAR¹; I. Fofana¹; F. Meghnefi¹; P. Picher²
Affiliations:
¹ Canada Research Chair tier 1, in Aging of Oil-Filled Equipment on High Voltage Lines (ViAHT), University of Quebec in Chicoutimi, QC G7H 2B1, Canada
² Hydro-Québec, Varennes, QC J3X 1S1, Canada
5. Paper 1226
Impact of Wavelet Filtering Strategies on TDOA Accuracy for Partial Discharge Localization: A Comparative Analysis
Authors: L. Farias Rocha¹; G. Victor Rocha Xavier¹; A. Carlos dos Santos Júnior³; H. Sales Silva²
Affiliations:
¹ Federal University of Sergipe, Brazil
² University of Brasília
³ Federal University of Rondônia
6. Paper 1238
Vacuum-Excited Laser Shearography for Nondestructive Detection of Internal Air-Gap Defects in Composite Insulators
Authors: L. Li¹; H. Liu²; C. Zhou²; J. Liu¹; B. Cao¹; H. Mei¹
Affiliations:
¹ Tsinghua Shenzhen International Graduate School, Tsinghua University
² State Grid Shandong Electric Power Research Institute
• POSTER SESSIONS
Topic 1 - Transients and EMC in Power Systems: Lightning, Switching, Repetitive Transients
Poster Session 1
Paper 1141
Experimental Investigation of the 8/20 μs Impulse Current Withstand Capability of Parallel-Connected Transient Voltage Suppressor Diodes
Authors: N. Gkonou¹; G. Peppas²; E. Roussou¹; T. Tsovilis¹
Affiliations:
¹ Aristotle University of Thessaloniki, Greece
² Technical University of Crete
Paper 1159
Refined Calculation and Analysis of Lightning Strike Density for a 500 kV Transmission Line in a Mountainous Area
Authors: K. Tang¹; T. Yuan¹; Y. Yi²; K. Zhang¹; W. Sima¹; M. Yang¹
Affiliations:
¹ The State Key Laboratory of Power Transmission Equipment Technology, Chongqing University
² The State Grid Zhejiang Electric Power Co., Ltd., Wenzhou Power Supply Company
Paper 1326
Behavior of fabric with copper threads under lightning-like impulse current
Authors: J. Rodriguez¹; J. Cristancho¹; D. Rodríguez¹; F. Roman¹; M. Shigihara²
Affiliations:
¹ Universidad Nacional de Colombia, Colombia
² University of São Paulo
Poster Session 2
Paper 1129
Effect of Shield and Underbuilt Wire Relative Permeability During Lightning Events
Authors: J. E. Guevara Asorza¹; T. A. Papadopoulos²; J. Pissolato Filho¹
Affiliations:
¹ University of Campinas, Brazil
² Aristotle University of Thessaloniki, Greece
Paper 1130
Conductive Coupling Mechanism in Lightning Analysis of Overhead Transmission Lines: A Simplified Modeling Approach
Authors: J. E. Guevara Asorza¹; T. A. Papadopoulos²; J. Pissolato Filho¹
Affiliations:
¹ University of Campinas, Brazil
² Aristotle University of Thessaloniki, Greece
Paper 1134
Overvoltage Propagation and Insulation Coordination in Low-Voltage Networks with Electric Vehicle Charger Subjected to Direct Lightning Strikes
Authors: W. Bassi¹; D. de Souza²; M. Nunes³
Affiliations:
¹ University of São Paulo (USP), Brazil
² Federal University of Mato Grosso (UFMT), Brazil
³ Federal University of Pará (UFPA), Brazil
Paper 1145
Laboratory Investigation of Long-Duration Lightning Currents and Resulting Thermal Damage
Authors: H. Sueta¹; L. Caires¹; R. Zilles¹; D. de Souza¹˒²; M. Shigihara¹
Affiliations:
¹ IEE USP, Brazil
² UFMT, Brazil
Paper 1324
Analysis of a Lightning Accident in Peru from an EMC Perspective
Authors: F. Roman; J. Rodriguez; C. Rivera; E. Pineda; A. Cristancho
Affiliation:
Universidad Nacional de Colombia, Colombia
Paper 1346
Modeling of Spite Streamer-Type Discharges Using Plasma Fluid Models Under the Local Field Approximation (LFA)
Authors: C. Gomez; F. Roman
Affiliation:
Universidad Nacional de Colombia, Colombia
Topic 2 - High Voltage Measurement Techniques and Instrumentation
Poster Session 1
Paper 1110
A Systematic Method for Insulation Defect Localization in EV Hairpin Stators Based on PDIV Testing under AC Voltage
Authors: Q. Zhao; P. Wang
Affiliation:
Sichuan University, China
Paper 1217
Investigation of the dependence of the Ks-Factor on temperature using a solid rod
Authors: C. Brose; R. Plath
Affiliation:
Technische Universität Berlin, Germany
Paper 1356
Investigation of Corona-Generated Space Charge Effects on Electric Field Distribution in an Indoor HVDC Corona Cage under the Influence of Wind
Authors: J. S. Djeumen¹; H. M. Langa²; T. Sutherland¹
Affiliations:
¹ Vaal University of Technology, South Africa
² University of South Africa, South Africa
Poster Session 2
Paper 1307
High-Voltage Circuit Breaker Opening and Closing Speed Measurement Method Based on an Attention-Enhanced Siamese Network
Authors: S. Li¹; Y. Zhao¹; W. Cheng¹; G. Liu¹; H. Zhang²; X. Zhao²
Affiliations:
¹ School of Electrical Engineering and Automation, Hefei University of Technology, China
² State Grid Chongqing Electric Power Company Construction Branch, China
Paper 1218
Ks-factor measurement using multi-frequency square-wave excitation
Authors: C. Brose; R. Plath
Affiliation:
Technische Universität Berlin, Germany
Paper 1313
Correlation Between Local Overheating at the Upper Head of an Oil–Paper Bushing and Temperature Rise: An Electromagnetic–Thermal Coupled FEM Study
Authors: Q. Wang¹; Y. Zhao¹; Y. Qian¹; L. Fang²; F. Wang²
Affiliations:
¹ Electric Power Research Institute of Guangdong Power Grid, China
Topic 3 - High Voltage Insulation Systems: Gas, Liquid, Solid, and Vacuum Dielectrics
Poster Session 1
Paper 1103
Influence of Electrode Surface on the Factor of Electrode Distance and Gas Pressure under AC Stress
Authors: L. Tiedemann; M. Kurrat
Affiliation:
TU Braunschweig, Germany
Paper 1261
Effect of Gas Composition on AC Breakdown Performance of C5-Fluoroketone/Air Mixture
Authors: A. Subhana¹; N. Støa-Aanensen²; F. Mauseth¹; A. Eichelberg³; C. Franck³
Affiliations:
¹ Dept. of Electric Energy, NTNU, Norway
² SINTEF Energy Research, Norway
³ High Voltage Lab, ETH Zürich, Switzerland
Paper 1144
Micro-Mechanism of Fatty-Acid Chain Length and Unsaturation on Dielectric Properties of Plant-Based Synthetic Esters
Authors: L. Fang; F. Wang; B. Li; Z. Xia; Z. Gao; J. Li
Affiliation:
State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing, China
Paper 1190
Multiscale Numerical Investigation of Streamer Discharge in Liquid Dielectrics
Authors: C. Ming¹; C. Li²; J. Li²
Affiliations:
¹ Chongqing University, China
² State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing, China
Paper 1166
Lipase-Catalyzed Synthesis of Pentaerythritol Insulating Esters from C8 Fatty-Acid
Authors: Y. Sun¹; F. Wang¹; Y. Zhang¹; Z. Huang¹; J. Li¹; P. Guo²
Affiliations:
¹ State Key Lab of Power Transmission Equipment Technology, Chongqing University, Chongqing, China
² Shandong Electric Power Equipment Co., Ltd, Jinan, China
Paper 1191
Study on the Dielectric Properties of Liquid-Crystal-Modified Natural Ester Insulating Oil
Authors: Y. Zhao¹; J. Li¹; D. Liu²; C. Li¹; Z. Huang¹; M. Wu¹; S. Luo¹; M. Guan¹
Affiliations:
¹ Chongqing University, China
² Shandong Electric Power Equipment Co., Ltd., Jinan, China
Paper 1262
Partial Discharge Ageing Effects in C4F7N and CO2-Based Insulating Gas Mixtures
Authors: A. Subhana¹; N. Støa-Aanensen²; F. Mauseth¹
Affiliations:
¹ Dept. of Electric Energy, NTNU, Norway
² SINTEF Energy Research, Norway
Paper 1297
Temperature-Dependent Electrical Properties of EPDM for HVDC Cable Accessories
Authors: X. Yu; J. Liu; L. Cheng; W. Liu; Y. Zhou
Affiliation:
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an, China
Paper 1308
The Influence of Side-Chain Structure on the Electrical Properties of Silicone Oil
Authors: Y. Zhang; H. Mei; S. Cui; Z. Zuo; C. Wu; Y. Zhou; X. Liang
Affiliation:
Tsinghua University, China
Poster Session 2
Paper 1114
Influence of External Vacuum Interrupter Design on Flashover Pattern
Authors: K. Flügel¹; K. Schulze¹; D. Gentsch²; M. Kurrat¹
Affiliations:
¹ TU Braunschweig, Germany
² ABB AG, Germany
Paper 1115
Impact of Cellulose Particles on the Dielectric Performance of Insulating Liquids
Authors: J. Hornak; P. Trnka; Y. Yakuba; P. Kadlec; Z. Mokra; O. Michal
Affiliation:
University of West Bohemia, Czech Republic
Paper 1149
Thermal Performance Assessment for High-voltage Current Transformers
Authors: A. Leite Neto¹; E. Costa¹; P. Vilar¹; M. Rique¹; G. Lira¹; A. Andrade²; J. Melo¹; F. Andrade¹; F. Ferreira Júnior¹
Affiliations:
¹ Federal University of Campina Grande, Brazil
² Federal University of Rio Grande do Norte, Brazil
Paper 1162
Interpretation of Internal Partial Discharge PRPD Patterns Based on Capacitance Calculations
Authors: M. de Oliveira Souto Morais¹; A. Francisco Andrade²; E. Guedes da Costa¹; I. Felix Carvalho¹; N. de Macêdo Silva¹
Affiliations:
¹ Federal University of Campina Grande, Brazil
² Federal University of Rio Grande do Norte, Brazil
Paper 1176
Identification of Critical Cavity Positions for Partial Discharge Initiation in a 13.8 kV Pin Insulator
Authors: D. Araújo dos Santos¹; A. E. Dias dos Santos¹; A. Francisco Andrade²; E. Guedes da Costa¹
Affiliations:
¹ Federal University of Campina Grande (UFCG), Brazil
² Federal University of Rio Grande do Norte (UFRN), Brazil
Paper 1283
Analysis of breakdown processes in alternative gases using spreadsheets
Authors: L. Tiedemann; M. Kurrat
Affiliation:
TU Braunschweig, Germany
Paper 1298
Synergistic Multi-Property Enhancement of Epoxy Resin for High-Voltage DC Cable Accessories
Authors: J. Liu; X. Yu; L. Cheng; W. Liu; Y. Zhou
Affiliation:
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, China
Paper 1311
Optimization of Electrical Breakdown Testing of Insulation Materials in Air using Additive Manufacturing
Authors: A. Laufer; M. Kahn; N. Kaune; M. Kurrat
Affiliation:
TU Braunschweig, Germany
Topic 4 - Performance of Insulators under Environmental Stresses
Poster Session 1
Paper 1342
Failure Analysis of 220 kV Composite Insulator with Abnormal Color Layering
Authors: C. Gao¹˒²; X. Yan³; M. Lu²; W. Li³; L. Li¹
Affiliations:
¹ School of Electrical and Electronic Engineering, Huazhong University of Science & Technology, Wuhan 430074, Hubei, China
² State Grid Henan Electric Power Research Institute, Zhengzhou 450052, Henan, China
³ State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, Shaanxi, China
Poster Session 2
Paper 1310
Study of the Influence of the Number and Dimensions of Neighboring Structures on Lightning Protection
Authors: D. KHELIL¹; S. BOUAZABIA¹; P. MIKROPOULOS²; I. Fatma¹; H. Behidja¹
Affiliations:
¹ University of Science and Technology Houari Boumediene, Algeria
² Aristotle University of Thessaloniki
Topic 5 - High Voltage Cable Insulation: Materials, Aging, and Testing
Poster Session 1
Paper 1133
Thermal–Electrical–Economic Analysis of Duct-Bank Configurations for HV Underground Transmission Lines
Authors: B. B. R. Ponce¹; J. E. Guevara Asorza¹; R. A. de Araujo²; J. Pissolato Filho¹
Affiliations:
¹ University of Campinas, Brazil
² Federal University of Lavras, Brazil
Paper 1354
The Impact of Pre-Conditioning on tan delta variations in XLPE power cables During 500 Hz Accelerated Ageing Tests
Authors: A. O. Adeniyi¹; T. Sutherland²; H. Langa³
Affiliations:
¹ Vaal University of Technology, Vanderbijlpark, South Africa
² Vaal University of Technology, Vanderbijlpark, South Africa
³ University of South Africa, Florida Park, South Africa
Poster Session 2
Paper 1119
An improved method for thermogravimetric kinetic analysis of polymer insulation
Authors: F. Liu; X. Huang
Affiliation:
Shanghai Key Laboratory of Electrical Insulation and Thermal Ageing, Department of Polymer Science and Engineering, Shanghai Jiao Tong University, China
Topic 6 - Insulation Systems for High Voltage Transformers and Rotating Machines
Poster Session 1
Paper 1257
Surface Discharge Characteristics of Oil-Paper Insulation Based on Synchronous Measurement of White Mark Evolution and Partial Discharge
Authors: J. Cheng¹; J. Chen¹; Y. Zhou¹˒²; G. Jiang²; W. Lyu²
Affiliations:
¹ Department of Electrical Engineering, Tsinghua University, Beijing, China
² School of Electrical Engineering, Xinjiang University, Urumqi, China
Paper 1101
Utilizing Non-Symmetrical Voltage Impulses for Performance Evaluation of Hairpin Motor Insulation
Authors: T. Hammarstroem; Y. Serdyuk
Affiliation:
Chalmers University of Technology, Sweden
Poster Session 2
Paper 1125
Assessment of Oil–Paper Insulation Systems with Various Solid Insulation Materials in Mineral, Synthetic, and Natural Ester Oils
Authors: P. Trnka; Z. Mokra; E. Mullerova; J. Hornak; E. Mullerova
Affiliation:
University of West Bohemia, Czech Republic
Paper 1267
Effect of Tween 80® surfactant on the stability of insulating nanofluids for high-voltage transformers
Authors: M. Marques; M. E. González; E. Wanderley Neto
Affiliation:
UNIFEI, Brazil
Topic 7 - Grounding Systems
Poster Session 1
Paper 1273
Quantifying the Influence of Seasonal Soil Moisture Variations on Grounding Systems of Different Scales
Authors: A. F. Andrade¹; M. C. Rique²; E. G. Costa²
Affiliations:
¹ Federal University of Rio Grande do Norte, Brazil
² Federal University of Campina Grande, Brazil
Paper 1325
Assessment of Tower Footing Resistance and Electrical Safety of T-Pylon Earthing Systems
Authors: A. R. Justo de Araujo¹; M. Albano¹; D. Clark¹; S. Robson¹; M. Shaban²; D. Guo²; M. Haddad¹
Affiliations:
¹ Cardiff University
² National Grid Electricity Transmission
Poster Session 2
Paper 1139
An Approach for Generating Ground Potential Rise Based on the Numerical Calculation of Harmonic Impedance under Realistic Conditions
Authors: A. R. Justo de Araujo; J. L. Aslan D'Annibale; J. S. Leon Colqui; J. P. Filho
Affiliation:
University of Campinas, Brazil
Topic 8 - Insulation Challenges in UHV AC and DC Power Systems
Poster Session 1
Paper 1329
Interlayer-spacing-tunable Multilayer Nanocoating Enhancing Corona Resistance of Organic Dielectrics
Authors: N. Guo; M. Dabaghian; A. Konstantinou; D. Wei; W. Zhong; L. Sun; Y. Cao
Affiliation:
University of Connecticut, United States of America
Poster Session 2
Paper 1247
Self-healing Properties of Metalized Biaxially Oriented Polypropylene Film with Large Temperature Difference
Authors: X. Liu¹; J. Lu¹; Q. Jia²; Z. Li¹; L. Cheng¹
Affiliations:
¹ State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Shaanxi, China, 710049
² Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Gansu Lanzhou 730000, China
Topic 10 - Novel Insulation Materials for High Voltage Applications
Poster Session 1
Paper 1168
Enhancement of Insulation Performance of Epoxy Resin Composites using Metal-Organic Frameworks
Authors: G. Zhang¹; X. Kong¹; H. Liu¹; L. Yang²; Z. Song¹; B. Du¹
Affiliations:
¹ School of Electrical and Information Engineering, Tianjin University
² Guangzhou Power Supply Bureau of Guangdong Power Grid Co., Ltd
Paper 1188
Breakdown Strength Enhancement of High-Temperature Polymer Films by UV Irradiation
Authors: Y. Tang¹˒²; C. Ren¹˒²; C. Zhang¹; W. Li¹˒²; C. Zhang¹˒²; T. Shao¹˒²
Affiliations:
¹ Beijing International S&T Cooperation Base for Plasma Science and Energy Conversion, Institute of Electrical Engineering Chinese Academy of Sciences
² University of Chinese Academy of Sciences
Paper 1213
High temperature power frequency of dynamic cross-linked composite resin under temperature gradient
Authors: J. Hu; W. Xu; Z. Huang; Y. Zhang; J. Li
Affiliation:
Chongqing University, China
Paper 1286
Simulation of Coil Breakdown Discharge Tests and Analysis of Gas Generation and Diffusion Behavior in Multi-Component Mixed Insulating Oil Transformers
Authors: M. Li; J. Hao; J. Wu; G. Lian; H. Zhang
Affiliation:
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
Paper 1295
Fluorinated Polyimides Modified with Polar End Groups for High-Temperature Capacitive Energy Storage
Authors: Y. Zhao; X. Yu; Y. Chen; W. Wang; L. Cheng; W. Liu; Y. Zhou
Affiliation:
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Poster Session 2
Paper 1155
Broadband Dielectric Spectroscopy Analysis of Nanocomposites using ColeFIT Automation Software
Authors: O. Michal; Z. Frana; P. Trnka; J. Hornak
Affiliation:
University of West Bohemia, Czech Republic
Paper 1173
Electrical and Mechanical Properties of Fluoropolymer-Based Insulating Thin Films
Authors: J. Cernohous; P. Trnka; O. Michal; J. Hornak
Affiliation:
University of West Bohemia, Czech Republic
Paper 1199
Interface Tracking Characteristics Between Epoxy Resin Modified by ZrW₂O₈ and Silicone Rubber at Low Interface Pressure
Authors: X. Kong¹; L. Geng¹; Q. Li²; B. Du¹
Affiliations:
¹ Tianjin University
² China Electric Power Research Institute
Paper 1222
Enhanced Dielectric Strength of Nano-SiO₂-Epoxy Vitrimer Composite under High Temperature Gradient
Authors: W. Xu¹˒²; J. Hu¹˒²; Y. Zhang¹˒²; Z. Huang¹˒²; P. Zhang¹˒²; J. Li¹˒²
Affiliations:
¹ State Key Laboratory of Power Transmission Equipment Technology
² School of Electrical Engineering, Chongqing University, Chongqing, China
Paper 1294
UV-Irradiation Enabled Charge Transport Regulation in Fluorene Polyester Films for High-Temperature Capacitive Energy Storage
Authors: Y. Chen; J. Liu; Y. Zhao; W. Wang; L. Cheng; W. Liu; Y. Zhou
Affiliation:
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an, China
Paper 1296
Effect of Triamine Crosslinking Junction Architecture on the High-Temperature Capacitive Energy Storage Performance of Polyimides
Authors: T. Him; Y. Chen; Y. Zhao; L. Cheng; W. Liu; Y. Zhou
Affiliation:
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an, 710049, China
Topic 11 - Insulation Aging, Space Charge Dynamics, and Industrial Applications
Poster Session 1
Paper 1154
Mechanism Study of Capacitance Loss of Metallized Film Capacitor Based on Deep Learning
Authors: J. Zhao¹; Z. Li¹; Z. Zhu¹; Y. Zhou¹; L. Cheng¹; W. Liu¹; B. Gai²; B. Liu²; H. Jia²
Affiliations:
¹ School of Electrical Engineering, Xi'an Jiaotong University, China
² Xi'an Power Capacitor Research Institute, Xi'an High Voltage Apparatus Research Institute Co., Ltd., Xi'an, China
Paper 1177
Influence of Surface Contamination on Power Loss in Ceramic Insulators.
Authors: A. Cardoso¹˒⁵; F. de Jesus²; A. Araújo³; B. Silva¹˒⁴; J. Ferreira¹; R. Silva⁵; M. Nunes⁵; W. Bassi⁶
Affiliations:
¹ University of Porto, Portugal
² Polytechnic Institute of Porto, Portugal
³ State University of Campinas, Brazil
⁴ INESC-TEC, Portugal
⁵ Federal University of Pará, Brazil
⁶ University of São Paulo, Brazil
Paper 1224
Dissimilarity analysis applied to statistical descriptors of pulse-count distributions from PRPD in UHF measurements
Authors: Í. M. C. Dantas¹; A. C. dos Santos Júnior²; G. V. R. Xavier¹; T. V. Ferreira¹; A. J. R. Serres³
Affiliations:
¹ Federal University of Sergipe, Brazil
² Federal University of Rondônia, Brazil
³ Federal University of Campina Grande, Brazil
Paper 1323
Multifactor Aging of High Temperature Motorrettes
Authors: R. Walker; W. Zhong; W. Zhang; Y. Cao
Affiliation: University of Connecticut, United States of America
Poster Session 2
Paper 1175
Evaluation of initiating conditions for surface degradation in ZnO varistors through computer simulations
Authors: A. E. Dias dos Santos¹; D. Araújo dos Santos¹; A. Francisco Andrade²; E. Guedes da Costa¹
Affiliations:
¹ Federal University of Campina Grande (UFCG), Brazil
² Federal University of Rio Grande do Norte (UFRN), Brazil
Paper 1187
Performance and Mechanism Analysis of Silicone Rubber for Composite Insulators under Thermo-Oxidative Aging
Authors: H. Zhou¹; Q. Wang¹; Z. Zuo¹; K. Wang²; C. Wu¹; X. Liang¹
Affiliations:
¹ Tsinghua University, China
² CCS Graduate School of Mobility, KAIST, Daejeon, Korea
Paper 1241
Effect of Thermal Aging on the Dielectric Properties of Silicone Oil and Mineral Oil
Authors: H. Mei¹; Z. Zuo¹; C. Wu¹; X. Liang¹; L. Wang²; Q. Wang²; Y. Zhao²
Affiliations:
¹ Tsinghua University, China
² State Grid Beijing Electric Power Company, China
Paper 1304
Evaluation of Surge Arresters Aging Using Partial Discharges and Physicochemical Analyses
Authors: T. Fagundes; E. Neto; C. Salles; T. Carneiro; C. Aguiar
Affiliation: Federal University of Itajubá, Brazil
Topic 12 - Reliability and Maintenance Strategies for High Voltage Apparatus
Poster session 1
Paper 1161
Technological Innovation and Maintenance Challenges in Energized High-Voltage Transmission Lines: Regulatory Perspectives and Applications in the Brazilian Context
Authors: A. Chalegra¹; W. Bassi²; D. Souza¹
Affiliations:
¹ Federal University of Mato Grosso – UFMT, Brazil
² University of São Paulo – USP, Brazil
Paper 1268
Causes of Outages in Electric Power Transmission Lines: An International Review and Analysis of the Brazilian Case
Authors: I. Moulaz¹; A. Chalegra¹; W. Martins Júnior¹; J. Lopes Junior²; D. Souza¹
Affiliations:
¹ Federal University of Mato Grosso – UFMT, Brazil
² Lightsource BP, Brazil
Paper 1349
Reliability Analysis with Parameters Uncertainty Assessment Applied to High-Voltage Equipment
Authors: L. I. M. Silva; A. F. Andrade
Affiliation:
Federal University of Rio Grande do Norte, Brazil
Poster session 2
Paper 1198
Diagnosis of Polluted Polymeric Insulators Using Thermal Dissimilarity via Dynamic Time Warping
Authors: B. Araujo¹˒²; J. Oliveira³; G. Rodrigues¹˒²; G. Xavier²˒³; A. Serres¹; T. Ferreira²˒³
Affiliations:
¹ Universidade Federal de Campina Grande, Brazil
² INESC P&D Brasil
³ Universidade Federal de Sergipe, Brazil
Paper 1260
A Health-Risk Integrated Asset Maintenance Decision Framework for High-Voltage Power Transformers
Authors: D. Abideen; F. Bahdad
Affiliation:
King Abdulaziz University, Saudi Arabia
Topic 13 - Online Condition Monitoring and Fault Diagnosis in High Voltage Equipment
Poster session 1
Paper 1148
Intelligent Asset Management Framework for Power Distribution Systems
Authors: B. Vieira¹; P. Vilar¹; I. Santos¹; J. V. Melo¹; G. Galdino¹; A. Leite Neto¹; G. Lira¹; V. Sgotti²; A. G. Benitez³; D. Laube⁴; M. Macedo⁴
Affiliations:
¹ Federal University of Campina Grande, Brazil
² Informa Software, Brazil
³ Sinapsis Energia, Brazil
⁴ Copel Distribution, Brazil
Paper 1163
Development of a Self-Calibrating TMR Sensor with Low Sensetivity Drift
Authors: H. Zhang¹; S. Pan¹; X. Liu¹; Y. Ye¹; S. Wu¹; J. Yang²; Z. Hu²; J. Hu¹
Affiliations:
¹ Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
² Guangzhou Branch, EHV, CSG
Paper 1164
Evaluation of Clustering Algorithms for Multiple Partial Discharge Sources
Authors: H. Santos Crispim¹; J. Victor Jales de Melo¹; A. Francisco Leite Neto¹; M. Cavalcante Rique¹; P. Bezerra Vilar¹; G. Rossany Soares de Lira¹; E. Guedes da Costa¹; F. do Nascimento Madia²
Affiliations:
¹ Federal University of Campina Grande, Brazil
² Isa Energia Brasil
Paper 1180
A load monitoring method for wind turbine blades based on built-in sensing Fiber Bragg Grating
Authors: X. Duan¹; Y. Peng¹; Z. Tang²; H. Tian¹; H. Liu¹; W. Zhang¹; T. Liu¹; K. Chen¹; W. Chen¹
Affiliations:
¹ Chongqing University, Chongqing, China
² State Grid Chongqing Electric Power Company Jiangbei Power Supply Branch, Chongqing, China
Paper 1192
Study on Vibration Characteristics of Bolt Loosening Defects in Cable GIS Terminations
Authors: Z. Zhang; Z. Jia
Affiliation:
Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
Paper 1206
Categorizing tap-changer faults through DGA and field based case studies
Authors: A. Bergstrom
Affiliation:
Hitachi Energy, Sweden
Poster session 2
Paper 1240
Vibration-Based Detection of Partial Discharge in Internal Insulation of Cable GIS Termination
Authors: Z. Zhang; Z. Jia
Affiliation:
Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
Paper 1255
Condition Monitoring of SF6 High-Voltage Circuit Breakers Based on Closing Coil and Primary Circuit Current Features
Authors: D. Silva¹; A. Coelho¹; I. Faria¹; C. Sousa¹; G. Vitor¹; R. Tozzi¹; C. Pessoa²
Affiliations:
¹ Federal University of Itajubá, Brazil
² AXIA Energia
Paper 1306
Distributed Acoustic Sensing–Based Partial Discharge Detection and Localization in Gas-Insulated Lines
Authors: H. Liu; J. Wang; Z. Wang; P. Yuan; G. Ma
Affiliation:
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, P.R. China, 102206
Paper 1332
Technical Evaluation of Online Condition Monitoring Techniques for High-Voltage Substation Equipment: A South African Utility Case Study
Authors: T. Madonsela
Affiliation:
ESKOM, South Africa
Paper 1364
Enhancing Transformer Fault Classification Using Spectral Entropy and Bioinspired UHF Antenna Measurements
Authors: A. Khoury Filho¹; B. Castro¹; J. Ardila-Rey²
Affiliations:
¹ São Paulo State University (UNESP), Department of Electrical Engineering, Bauru Campus, Brazil
² Universidad Técnica Federico Santa María (USM), Department of Electrical Engineering, Santiago, Chile
Topic 14 - Emerging Trends in High Voltage Engineering: Materials, Technologies, and Applications
Poster session 1
Paper 1152
Machine Learning-Based Frequency Spectrum Clustering of Partial Discharge Defects in Gas-Insulated Systems Filled with Technical Air and C4-Mixture
Authors: R. Ullah¹; A. Reid¹; M. Haddad¹; M. Barnett²; P. Taddei²
Affiliations:
¹ Cardiff University, United Kingdom
² SSEN Transmission UK
Paper 1205
Ru₃-Cluster-Modified ReS₂ Monolayer for Transformer DGA H₂ Sensing: A First-Principles Study
Authors: Y. Yang; F. Wang; Z. Xia; Z. Gao; J. Li
Affiliation:
State Key Lab of Power Transmission Equipment Technology, Chongqing University, China
Paper 1347
Wavelet-Based Multiscale Feature Extraction for Interpreting SFRA and Classifying Winding Deformations and Short-Circuits in Power Transformers
Authors: I. Souza dos Santos¹˒²; M. Petraglia Rembold¹; I. Fofana³; D. Silva de Souza²; S. Beki³; M. Beheshti Asl³
Affiliations:
¹ Federal University of Rio de Janeiro (UFRJ), Brazil
² Eletrobras Cepel – Electric Energy Research Center, Brazil
³ Université du Québec à Chicoutimi (UQAC), Canada
Poster session 2
Paper 1126
Flashover Voltage Increasement of Epoxy Resin Exposed to Non-uniform Electric Fields by Pulse-actuated PECVD
Authors: L. Deng; Z. Huang; B. Shu; X. Chen; Y. Mi
Affiliation:
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, P. R. China
Paper 1158
Cross-Modal Deep Learning for Partial Discharge Recognition and Localization in GIS
Authors: G.-J. Zhang; Y.-Q. Liu; S.-Q. Wang; W.-D. Li
Affiliation:
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049, China
Paper 1350
DTVA Dataset: A Dataset for Visual Anomaly Detection in Distribution Transformers
Authors: P. E. Oliveira de Andrade; M. W. Galdino de Sena; P. Bezerra Vilar; G. R. Soares de Lira; H. Santos Crispim; B. Alencar Vieira
Affiliation:
Federal University of Campina Grande, Brazil
Topic 16 - Renewable Energy Integration to High Voltage Grids and Related Technologies
Poster session 1
Paper 1150
Modeling of Inverter-Based Resources (IBRs) for Stability and Security Studies in Power Systems
Authors: M. Rique; G. Lira; P. Vilar; A. Leite; J. Melo
Affiliation:
Federal University of Campina Grande, Brazil
Paper 1340
Automated EMT Model Generation for Distribution System Analysis
Authors: M. Bastos¹; G. Prezotto¹; L. Lourenço²; M. Salles¹; R. Monaro¹; H. Khan¹; F. Morais¹
Affiliations:
¹ Engineering School of the University of São Paulo (Poli-USP), Brazil
² Institute of Energy and the Environment (IEE-USP), Brazil
Poster session 2
Paper 1305
Descriptor State-Space Modeling of Synchronous Generators for Small-Signal Stability Studies in Modern Power Systems
Authors: A. M. Yojo de Lima¹; E. Gurski²; L. F. Normandia Lourenço²
Affiliations:
¹ Polytechnic School, University of São Paulo (USP), Brazil
² Institute of Energy and Environment (IEE), University of São Paulo (USP), Brazil
Paper 1337
A Matlab-based Application for Impedance Measurement of Power Electronic Systems
Authors: A. K. Santos Cardoso da Silva¹; G. Carvalho Prezotto¹; F. Eduarda N. Morais¹; H. Jan Khan¹; R. Machado Monaro¹; M. Barbosa de Camargo Salles¹; L. Felipe Normandia Lourenço²
Affiliations:
¹ Engineering School of the University of São Paulo (Poli-USP), Brazil
² Institute of Energy and the Environment (IEE-USP), Brazil
Topic 17 - Smart Materials and Adaptive Systems for High Voltage Engineering
Poster session 1
Paper 1189
Quantum Chemical Evaluation of Phenolic Antioxidants for Enhancing Oxidative Stability of Ester-Based Transformer Insulating Oils
Authors: M. Wu¹; J. Li¹; P. Wang²; C.-H. Li¹; S. Luo¹; Z. Huang¹
Affiliations:
¹ State Key Laboratory of Power Transmission and Transformation Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
² Shandong Electric Power Equipment Co., Ltd., Jinan, 250022, China
Topic 18 - High Voltage Engineering Education and Workforce Development
Poster session 1
Paper 1121
High Voltage Impulse Testing: A Simulator Based on Virtual Reality and Artificial Intelligence
Authors: N. de Macêdo Silva¹; J. Fernandes de Araújo¹; Á. Meton Sousa Perdigão²; Y. Clemente Dantas Reis¹; Y. Emanoel Pereira Dias¹; M. de Oliveira Souto Morais¹
Affiliations:
¹ Federal University of Campina Grande, Brazil
² Vale S.A., Brazil
Poster session 2
Paper 1274
Understanding Interfacial Polarization Effects in Layered Dielectric Systems Through Numerical–Analytical Modeling
Authors: A. F. Andrade¹; E. G. Costa²
Affiliations:
¹ Federal University of Rio Grande do Norte, Brazil
² Federal University of Campina Grande, Brazil
Paper 1359
Proposal for an Open-Source Reference Model for Electromagnetic Field Transient Simulations
Authors: C. K. Arruda¹; A. F. Rosa¹; L. F. França¹˒²
Affiliations:
¹ CEPEL, Brazil
² Federal University of Rio de Janeiro (UFRJ), Brazil
Topic 19 - Electromagnetic Fields: Computation, Measurement, and Applications
Poster session 1
Paper 1358
Direct Integrity Assessment of Conductive PPE Using Internal Electric Field Mapping
Authors: A. Franco¹; A. Mpalantinos Neto²; C. R. Nunez Barbosa²; L. A. M. C. Domingues²
Affiliations:
¹ CEPEL, Brazil
² Independent Consultant
Poster session 2
Paper 1230
A Different Approach in Space Dimension for Partial Discharge Modelling Using Finite Element Method
Authors: A. Ribeiro¹˒²˒³; M. V. Nunes¹˒²˒³; A. Silva¹˒²˒³; C. Silva¹˒²˒³; A. de Morais¹˒²˒³; A. Manito¹˒²˒³; R. Silva¹˒²˒³; W. Bassi⁴
Affiliations:
¹ Federal University of Pará, Brazil
² Guamá Science and Technology Park, Brazil
³ High and Extra High Voltage Laboratory, Brazil
⁴ University of São Paulo, Brazil
Topic 20 - Standardization and Safety Protocols in High Voltage Engineering
Poster session 2
Paper 1259
A Factor-Driven Reporting Framework for AC and DC Breakdown Testing of SF6-Alternative Gas Insulation
Authors: F. Bahdad; D. Abideen
Affiliation:
King Abdulaziz University, Saudi Arabia